Techkon SpectroJet w/ ExPresso
Scan-Measurement Device SpectroJet
SpectroJet is a "spectro-photometer on wheels“ which automatically measures the densities and color values of process and spot-colors and simultaneously transfers the measurement data to a PC within seconds.
It revolutionizes automatic measurement on any color control bar for any printing process. The device is simply guided by hand along the color test patches. Tracking wheels on the bottom ensure a straight run.
Simultaneously the accurate, spectral measurement data is sent to the PC where all relevant information for controlling the printing press is displayed.
SpectroJet is equipped with a high resolution spectral sensor element including a true physical, switchable polarizing filter which analyzes the color samples under standardized conditions meeting ISO and Gracol G7 requirements. The measurement data can be exported into other software applications that connect real-time to printing presses to enable a ‘closed loop ’ turn-key solution. One unique feature is its flexibility to be used with any press type or format. It is delivered as a complete turn-key system.
SpectroJet and the related PC-software ExPresso are practical utilities that adhere to standards as for example ISO 12647 and Gracol G7.
SpectroJet Basic Model supports density only and the SpectroJet Pro model supports spectral measurements.
Measurement method: Spectral remission measurement and color density measurement according to ISO 5-3/4
Measurement geometry: 0/45° optics to DIN 5033
Measurement aperture: 1,5 mm, appropriate for measuring patches with at least 3 mm height and 3 mm width. UV cut filter optional
Light source: Gas filled lamp, type A illumination
Polarization filter: Twice linear crossed, switched on and off per software command
Measurement time: Approx. 160 mm/s (equals approx. 4 seconds for 520 mm sheet length); single measurement approx. 1 second
White reference: Absolute and relative
Illumination types / Standard observer: A, C, D50, D65, F / 2°, 10°
Density filter: DIN 16536, DIN 16536 NB, ISO/ANSI T, ISO/ANSI I, ISO E, spectral density Dmax
Density measurement range: 0.00 – 2.50 D
Repeatability: 0.01 D, 0,03 CIE dEab
Production Spread: 0.01 D, 0,3 CIE dEab
Data transmission: USB-connection
Power Supply: AC Adapter 110 – 240 V, 47 – 63 Hz
Dimensions / Weight: 70 x 135 mm, 360 grams
Accessories: Software TECHKON ExPresso Basic Software TECHKON ExPresso Pro Print Control Strip TCS Digital Horizontal Guidance Track in different length
|
|
|
Follow us